Pellerin Milnor Corporation

Technical Knowledge Base

Data Unlocatable

Data Unlocatable message
When I try to run a remote formula I receive the error "Data Unlocatable", what do I check for?
Data Unlocatable is normally due to an addressing problem look at the following:

1) At the machine:
a) The remote local switch is set to Remote.
b) The Mildata address is set correctly.


2) In the Mildata:
a) The machine type is set correctly.
b) The Mildata address is set correctly.
c) The Machine's address is unique.
d) The Programmer location is set correctly and done once for every machine.
e) The programmer communication dll is set correctly and done once for every machine.
f) The COM port is set correctly.
g) The machine's display is shown in the Mildata monitoring screen.
h) File/Configure/Advanced make sure that the box "Formula Router" is not checked.

3) In the machine PC Programmer:
a) One unique machine exists with the correct Mildata address.
b) The group containing that machine has the formula desired.
c) One remote code exists for the formula desired.
d) The remote code matches code you are entering in at the machine.


SES 3/12/03
Last updated: 03/12/2003 / Node ID: 719 / Key Chain: 12.1.2C9.2CB.2CF.