Pellerin Milnor Corporation

Technical Knowledge Base

Chem Inlet Box

Problems with chemical inlet boxes leaking.
Problem: Chemical inlet box leaks chemicals and water when flushing. The box also appears to expand when the flush valve is open.
On G3 and G4 CBW's the chemical box flush water is now regulated to prevent pressurization of the chemical box. Kit part number KTG3CFPR01 is available to add this regulator and associated piping to any CBW that was shipped prior to the addition of the flush water regulator.

See attached instructions for pictures and guidance.



GLL 10-17-05
Last updated: 10/17/2005 / Node ID: 1195 / Key Chain: 12.1.7F.4AA.4AB.