1. Connect the data storage device cable to the transfer port on the back of the MILTRON. The ready light on the data storage device will come on.
2. Insert programming key into the Black Box and turn the key to clear the memory. The ready light on the black box will go out. After a short period the ready light will come back on. Turn the key back to the original position and remove the key from the black box.
3. Press Ctrl - K on the MILTRON.
4. Press Ctrl - T.
5. Press Escape.
6. Enter the Password.
7. Press Escape twice.
8. Turn program key on MILTRON.
9. Press the "Line Feed" key on MILTRON to advance the cursor to "Data Storage Options"
10. Press Return
11. Move the cursor to "Interrogate Data Storage Device" and press "Return." If the Data Storage Device is properly connected to the MILTRON, the "Xfer Status" on the bottom of the MILTRON screen will read "Data Device Rdy." If this message is not displayed, do not continue until connections are checked and the proper message is displayed.
12. Press "Line Feed" until the cursor highlights "Upload to Data Storage Device."
13. Press Return
14. The "Receive" light on the Data Storage Device will come on.
15. After the light goes off, the "Xfer Status" on the bottom of the MILTRON screen will read "Upload Complete". (If any other message is displayed, then an error has occurred and the upload was not successful).
16. Press Escape until you have returned to the Main Screen of the MILTRON.
17. Turn key to the run position.
18. Press Ctrl - D to restart the CBW.

mrs 5-29-01