Ope02

OPE02 PARAMETER SETTING OUT OF RANGE

In the normal Operations menu, look at parameter U1-34 to see the parameter that is out of range.
Adjust the parameters to their normal values. In every machine, there should be a page that is placed inside of a plastic sleeve listing the inverter constants for that type of inverter and that particular model of Milnor machine.

When in doubt, initilize the inverter will restore the inverter to Yaskawa factory defaults. Then program each constant based on the Milnor supplied page of paper.

CSH 01-15-09
Last updated: 01/15/2009 / Node ID: 1607 / Key Chain: 12.1.74.645.647.