Running older Drynet Versions with a new Siemens PC will require adding a parrallel port card to the computer. When this is done, in some cases depending on the version of software, you may get an error stating that DLPORTIO.SYS is not found.
1. Download the DLPORTIO.sys file and copy into the following folder C:windowssystem32.
2. Download the Services.exe file and double click on the file to start a Services Creation Application.
3. Fill in the data in the following blocks of the Services Creation Application. See the attached file Service.jpg for a screen shot of the Services Creation Application with the data in the correct blocks
Select "List All Services"
Type the Service Name using all capital letters "DLPORTIO"
Type Display Name using all capital letters "DLPORTIO"
Set Startup
Last updated: 02/12/2009 / Node ID: 1617 / Key Chain: 12.1.64F.650.651.