Pellerin Milnor Corporation

Technical Knowledge Base

Deck Failures

50 KG press bed structural deck failures and repair considerations.
See the attachment for 50KG press bed replacement and the possibilities of structural deck failure underlying the perforated bed.
This document is intended to educate users before purchasing and installing a new perforated press bed cover sheet and the associated parts under the sheet. If the structural components are failed under the perforated sheet, zig zags and liner tray then the success of the part replacement will be jeopardized. See the attachment for details.

An engineering drawing and template were made for drilling the holes in the press deck plate. The template is not needed to accomplish the work. marking and center punching the hole locations is sufficient.
The only parts needed are threaded rods, grade 5 or better, and 1" nuts to turn the threaded rod into the tapped holes.
the threaded rod part number is X7 20798 and is simply a 16" threaded rod made from 1" 8 TPI threaded rod, Milnor part number, 17R032. the nuts are part number 15G250.

GLL 01-04-08




key words:
diaphragm failure
2 stage press frame
deck plate
decking
lower frame
press bed
bed failure
Last updated: 01/04/2008 / Node ID: 1538 / Key Chain: 12.1.86.1F5.601.602.